DROP TEST> CYANURIC ACID (20-100 ppm)
COMPONENTS:
1 x 5094 Instruction 1 x 9193 Sample Tube, CYA View, Graduated, 20-100 ppm (10 ppm div.), plastic 1 x 9194 Bottle, CYA Dispensing, Calibrated 15 mL, plastic w/cap 4 x R-0013 Cyanuric Acid Reagent, DC
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.KEEP REAGENTS AWAY FROM CHILDREN.
1. Rinse and fill CYA dispensing bottle (#9194) to 15 mL mark with water to be tested.
2. Add R-0013 Cyanuric Acid Reagent to neck. Cap and mix for 30 seconds. Sample will turn cloudy if cyanuric acid is present.
3. Viewing from top, slowly transfer cloudy solution to CYA view tube (#9193) until black dot on bottom of CYA view tube just disappears.
4. Read CYA view tube at liquid level. Record reading as parts per million (ppm) cyanuric acid.
|